On a Norweco Singulair Green system with a Service Pro control center, a flashing red light means the control center has detected a problem with the aerator. The pattern of the flashes tells you which kind. This guide explains the patterns, what the reset button does, and what to tell your dealer.
It is based on Norweco’s owner’s manual for the Singulair Green Models 960 and TNT. Other Norweco models and older control centers can behave differently. Check the model on your control center’s data plate and use its manual.
What the red light patterns mean
| What you see | What the manual says it means |
|---|---|
| Two short flashes, then a three second pause, repeating | Open motor or under-current condition |
| Even, steady flashing | Over-current condition. It continues until serviced. |
| Red light flashing, no sound | The control center is still trying to restart the aerator, or the audible alarm has been silenced |
| Red light flashing and audible alarm | The aerator did not restart after two hours of attempts |
What the control center does on its own
When it detects an aerator problem, the red light starts flashing and the control center tries to restart the aerator every five minutes for two hours. If the aerator still has not restarted after two hours, the audible alarm sounds.
So a flashing light without sound is not a false alarm. It is the first stage.
What the reset button does
The reset button is on the control center cover. Pushing it silences the audible alarm and makes the control center try to restart the aerator. Often that returns the aerator to normal operation.
If the problem is still there, the manual says the audible alarm stays silenced for 48 hours, but the light keeps flashing. At that point the manual’s instruction is to contact your local Singulair Green dealer.
In other words: press reset once. If the light is still flashing afterwards, the alarm is quiet but the problem is not solved. Do not treat the silence as a fix.
High water and the aerator
The Singulair aerator is not designed to run under water. If liquid in the tank rises to the level of the foam restrictor, the control center shuts off power to the aerator and starts the same diagnostic sequence. A red light after very heavy water use or heavy rain may be telling you about the water level, not a failed motor.
Reduce water use and note what happened beforehand: laundry, guests, a storm. If rain seems to be the trigger, see sprinklers running when it rains.
What you can check safely
- The breaker. The control center is wired to its own dedicated circuit at the main electrical panel. See whether it has tripped. If it trips again after you reset it, stop and call the dealer.
- The vented cover over the aerator. Fresh air enters through a vent around the access cover. The manual says not to let plants, shrubbery, mulch or landscaping restrict it, and to keep the ground graded so runoff drains away.
- The light pattern. Write down exactly what it is doing and when it started.
What not to do
- Do not remove the aerator or attempt to repair it. The manual says unauthorized tampering or repair will void important provisions of the lifetime warranty and exchange program.
- Do not adjust the time clock. It is factory set, and the manual says the owner should not adjust it.
- Do not open the tank or leave any access cover unsecured.
- Do not do electrical work on the control center. Before any service, the manual requires the dedicated breaker to be shut off first, then the control center’s power switch.
What to tell the dealer
The dealer’s name, address and phone number are on the front of the control center. Before you call, have:
- The information on the control center data plate.
- The aerator serial number. Norweco indexes warranty and service records by owner name and aerator serial number, so this avoids delays if the home has changed hands.
- The light pattern, whether the audible alarm sounded, and whether you pressed reset.
- Recent events: a power outage, a storm, unusually heavy water use, tank pumping.
The telephone noise is not a fault
Some Service Pro control centers report to a monitoring center over the home telephone line. If you pick up the phone and hear a high-pitched digital signal, the manual says to hang up all phones on that line and wait a few seconds. The control center disconnects and frees the line.
Service and warranty points worth knowing
- At least four service inspections in the first two years are included in the original purchase price. The exact frequency is set by the local regulator.
- After that, the dealer offers a continuing service agreement. In many areas the regulator requires one.
- Pumps, filters, valves and irrigation components are not part of the Singulair Green service program. The manual says they should be covered by a separate maintenance agreement. If your system sprays, ask who covers the spray pump.
- If the warranty registration card was not returned within thirty days of installation, the warranty period starts from the factory shipping date instead.
For how service agreements differ, see septic maintenance contract types explained.
If your system is not a Singulair Green
Start with the general guide: aerobic septic alarm going off: what to check first. For Hoot systems see the Hoot control panel lights guide.
Sources
- Norweco, Singulair Green Bio-Kinetic Wastewater Treatment System, Models 960 and TNT with Service Pro Control Center, Owner’s Manual, for the alarm patterns, restart sequence, reset behavior, high-water shutoff, owner restrictions, service program and warranty registration.
General homeowner education only. This is an independent guide and is not affiliated with Norweco. Your own manual and your dealer control the correct procedure for your installation.
Last reviewed: November 10, 2026.